Electronic flow meter

Electronic move meters are industrial digital circulate meters used for fluid flow measurement. In many utility eventualities, people usually use electronic flowmeter is electromagnetic flowmeter.
Electronic flowmeter varieties, similar to electromagnetic flowmeter, vortex flowmeter and ultrasonic flowmeter. Electronic flowmeter for industrial liquids, water, pure gas, gasoline, gasoline, air. Electronic flowmeter converts the monitored fluid move into an digital signal. This contains pulse indicators, 4-20mA normal alerts, and so on.
They are not fully electronic in nature, but they represent a logical grouping of circulate measurement applied sciences. All of those meters have no transferring elements. They operate through highly refined electronics and circuitry.
Table of Contents

What is an digital flow meter?

Electronic move meter products

Electronic flowmeter types and working precept

Electromagnetic flow meter

Advantages of utilizing electromagnetic flowmeter

Disadvantages of utilizing electromagnetic flow meters

Vortex flow meter

Ultrasonic circulate meter

Advantages of ultrasonic flowmeters

Disadvantages of ultrasonic move meters

How to determine on your digital flow meter?

What is an electronic circulate meter?

A move meter is a device used to measure the quantity or mass of a gasoline or liquid. Flow meters have many names relying on the particular trade, such as circulate meters, flow indicators, liquid meters, circulate sensors, circulate meters, and so forth.
Electronic move meters are industrial digital flow meters used for liquid flow measurement. Common kinds of electronic move meters are electromagnetic, vortex and ultrasonic move meters.
Electromagnetic flowmeters are essentially probably the most simple electrical flowmeters with a primary operating principle derived from Faraday’s Law. Vortex flowmeters depend on piezoelectric sensors to detect vortex currents coming off a fixed shedding bar. And ultrasonic flowmeters owe their successful utility to classy digital signal processing.
Electronic circulate meter products

AYT Digital Liquid Magnetic Flow Meter

Learn More AYT Digital Liquid Magnetic Flow Meter

AFT Split Type Electromagnetic Flow Meter

Learn More AFT Split Type Electromagnetic Flow Meter

ACT Insertion Type Magnetic Flowmeter

Learn More ACT Insertion Type Magnetic Flowmeter

AQT Steam Vortex Flow Meter

Learn More AQT Steam Vortex Flow Meter

TUF Clamp On Ultrasonic Flow Meter

Learn More TUF Clamp On Ultrasonic Flow Meter

MHC Portable Ultrasonic Doppler Flow Meter

Learn More MHC Portable Ultrasonic Doppler Flow Meter

Electronic flowmeter sorts and dealing principle

Simply put, the working precept of digital flowmeter is to convert the flow price of the measured fluid into an electronic sign through the flow sensor meeting. And can be flow display and signal output. For example, display instantaneous move, cumulative move, and so forth. Roughly divided into the following 3 categories.
Electromagnetic flow meter

Electromagnetic circulate meters work primarily based on Faraday’s precept of electromagnetic induction. เกจวัดแรงดันไทวัสดุ is also recognized as solely conductive fluid can be utilized.
Magnetic move meter consists of a non-magnetic pipe lined with an insulating material. A pair of magnetic coils are positioned at right angles to the circulate and a pair of electrodes penetrate the pipe and its lining. When electrically conductive fluid flows via the pipe beneath the influence of a particular density magnetic field generated by the electromagnetic coil, the amount of voltage (E) generated throughout the electrodes is predicted by Faraday’s legislation to be proportional to velocity (V) proportional to the liquid.
E = KV

Where

E = the quantity of voltage generated at the electrode

V = velocity of the fluid flowing by way of the pipe

K=calibration fixed of the meter

Advantages of utilizing electromagnetic flowmeter

High accuracy and stability

Self-checking

Bi-directional measurement

No strain loss

No shifting parts

Possible for hygienic functions

Available in large sizes

Disadvantages of using electromagnetic flow meters

Cannot be used to measure gases, vapors and liquids containing giant amounts of gasoline

Can not be used to measure liquid media with very low conductivity Electromagnetic flowmeter can not measure media corresponding to petroleum merchandise or organic solvents

Can not be used to measure excessive temperature media. Currently restricted by the overall industrial electromagnetic flowmeter measuring tube lining supplies and electrical insulation materials.
Electromagnetic flowmeter is susceptible to the affect of external electromagnetic interference.
Vortex move meter

Vortex flow meters are sometimes made of 316 stainless-steel or Hastelloy and include a blunt body, a vortex sensor meeting, and transmitter electronics. When a non-streamlined object (also referred to as an obtuse body) is placed within the path of a high Reynolds number move, the fluid will alternately separate from the item on its downstream sides and, as As the boundary layer separates and coils back on itself, the fluid varieties vortices. These vortices result in areas of strain fluctuations detected by piezoelectric or capacitive sensors. Fluid velocity is dependent upon the frequency of the generated vortices and the Strouhal number and is given by the following equation

V = (fxh)/S

Where

V = average velocity of the fluid flow

f = frequency of the generated vortex

h = width of the obtuse physique

S = number of Strouhal

S varies with Reynolds number; however, it is virtually fixed over a extensive range of move charges.
In practice, a k-factor representing the variety of vortices generated per unit quantity is used as an alternative of S. Thus the volumetric circulate rate is

Q = f/K

Vortex circulate meters usually are not sometimes really helpful for dosing or other intermittent circulate applications. This is as a result of the drip flow setting of the dosing station may be under the minimal Reynolds number limit of the meter. The smaller the whole batch, the more significant the resulting error may be.
Low strain (low density) gases is not going to generate robust enough stress pulses, especially at low fluid velocities. Therefore, in this type of service, the gauge is prone to have a poor vary and won’t be able to measure low circulate charges. On the opposite hand, if the lowered range is appropriate and the meter is sized for normal move, then a vortex flowmeter should still be thought of.
The permanent pressure loss by way of the vortex flowmeter is about half that of an orifice flowmeter with about two velocity heads. (Velocity head is defined as V2/g, the place V is the circulate rate and g is the gravitational fixed in consistent units.) If the piping and instrumentation are properly sized and similar, the stress drop could additionally be only some kilos per square inch. However, downsizing (installing smaller than line size gauges) to extend the Reynolds number can enhance the head loss to greater than 10 psi. It can also be essential to make sure that the shrink stress isn’t lower than the vapor pressure of the method fluid, as this could result in cavitation. Naturally, if the again stress on the meter is lower than the steam stress, the method fluid will flash and the meter reading shall be meaningless.
The main advantages of vortex flow meters are their low sensitivity to modifications in process situations and low wear relative to orifice or turbine flowmeters. In addition, initial and maintenance prices are very low. For these causes, they have gained wider acceptance among customers.
Ultrasonic flow meter

The pace of sound propagation in a fluid is dependent upon the density of the fluid. However, if the density is fixed, the time of passage (or reflection) of ultrasound can be used to discover out the rate of the flowing fluid.
Ultrasonic flow meters measure fluid velocity by transmitting high-frequency sound waves along the fluid flow path. Fluid motion impacts the propagation of those sound waves, which can then be Then it can be measured to infer the fluid velocity. There are two primary kinds of ultrasonic flowmeters: Doppler and transmission time. Both types of ultrasonic flowmeters work by transmitting Both forms of ultrasonic move meters work by transmitting high-frequency sound waves into the fluid stream (incident pulse) and analyzing the acquired pulses.
Doppler move meters utilize the Doppler impact, which is a frequency shift caused by waves emitted or mirrored from a transferring object. Doppler flow meters mirror sound waves from bubbles or particles in the air stream Particulate material in the reflection of sound waves, measuring the frequency shift and inferring the fluid velocity and thus the flow rate based on the magnitude of that frequency shift.
In the design of a transit time ultrasonic flowmeter, the time of flight of the ultrasonic sign is measured between two transducers, one upstream and one downstream. With flow or The difference in time spent in opposition to the move determines the fluid velocity from which the move fee is inferred.
Advantages of ultrasonic flowmeters

The electronics in the ultrasonic flowmeter embody an ultrasonic flowmeter detector that compensates and adapts to modifications in fluid distribution, fluid kind and pipe materials.
Portable ultrasonic flowmeter converters can be utilized as a direct methodology of successfully determining circulate in comparability with different flow methods.
Compared to different mechanical flow meters, ultrasonic flow meter converters are inexpensive to use and keep as a outcome of they have no transferring parts in these circulate meters.
They are designed to be very exact and do not impede the flow of liquids, so they can be used for sanitary, corrosive and abrasive liquids.
Disadvantages of ultrasonic circulate meters

The major disadvantage of ultrasonic flowmeters is value. Compared to different forms of mechanical move meters, flow meters are very expensive .

Compared to mechanical move meters, ultrasonic move meters are more complicated and therefore require experts to repair and keep the move meters.
How to choose your electronic circulate meter?

The necessary elements when selecting a right move meter system are

Media to be measured

Accuracy

Cost

Flow vary

Operating requirements

Maintenance

Lifetime

Delivery time

These elements are kind of interrelated. For example – the price of a circulate meter increases with accuracy and high quality of life. Flowmeter calibration and maintenance are also essential to consider.
More articles on flowmeters:
Chilled water circulate meter

Ultrasonic flow meter working principle

Difference between move meter and move transmitter

Working precept of rotameter
Don’t let #keyword# drive you crazy because you’re afraid that you do not know where to begin. Information is useless unless you actually apply it and, for most people, the initial step is the one that is the most challenging for them to take. One more thing that you should do is click over to #links# and absorb some of the knowledge that they have collected for you.


Electronic circulate meters are industrial digital circulate meters used for fluid flow measurement. In many application eventualities, individuals typically use electronic flowmeter is electromagnetic flowmeter.
Electronic flowmeter varieties, similar to electromagnetic flowmeter, vortex flowmeter and ultrasonic flowmeter. Electronic flowmeter for industrial liquids, water, pure fuel, gasoline, fuel, air. Electronic flowmeter converts the monitored fluid circulate into an electronic signal. This includes pulse indicators, 4-20mA standard alerts, and so forth.
They aren’t absolutely electronic in nature, however they symbolize a logical grouping of circulate measurement applied sciences. All of these meters have no moving elements. They function via extremely subtle electronics and circuitry.
Table of Contents

What is an digital flow meter?

Electronic move meter merchandise

Electronic flowmeter types and working principle

Electromagnetic circulate meter

Advantages of utilizing electromagnetic flowmeter

Disadvantages of using electromagnetic flow meters

Vortex flow meter

Ultrasonic circulate meter

Advantages of ultrasonic flowmeters

Disadvantages of ultrasonic flow meters

How to decide on your digital move meter?

What is an electronic flow meter?

A circulate meter is a tool used to measure the amount or mass of a gasoline or liquid. Flow meters have many names relying on the particular business, such as move meters, flow indicators, liquid meters, move sensors, move meters, and so on.
Electronic circulate meters are industrial digital move meters used for liquid circulate measurement. Common kinds of digital move meters are electromagnetic, vortex and ultrasonic move meters.
Electromagnetic flowmeters are basically essentially the most straightforward electrical flowmeters with a first operating precept derived from Faraday’s Law. Vortex flowmeters depend on piezoelectric sensors to detect vortex currents coming off a hard and fast shedding bar. And ultrasonic flowmeters owe their profitable utility to stylish digital signal processing.
Electronic flow meter products

AYT Digital Liquid Magnetic Flow Meter

Learn More AYT Digital Liquid Magnetic Flow Meter

AFT Split Type Electromagnetic Flow Meter

Learn More AFT Split Type Electromagnetic Flow Meter

ACT Insertion Type Magnetic Flowmeter

Learn More ACT Insertion Type Magnetic Flowmeter

AQT Steam Vortex Flow Meter

Learn More AQT Steam Vortex Flow Meter

TUF Clamp On Ultrasonic Flow Meter

Learn More TUF Clamp On Ultrasonic Flow Meter

MHC Portable Ultrasonic Doppler Flow Meter

Learn More MHC Portable Ultrasonic Doppler Flow Meter

Electronic flowmeter varieties and working principle

Simply put, the working precept of electronic flowmeter is to convert the flow price of the measured fluid into an electronic signal by way of the flow sensor assembly. And can be flow display and signal output. For instance, show instantaneous move, cumulative circulate, and so forth. Roughly divided into the following 3 classes.
Electromagnetic flow meter

Electromagnetic circulate meters work based mostly on Faraday’s principle of electromagnetic induction. Electromagnetic flowmeter is also referred to as only conductive fluid can be utilized.
Magnetic circulate meter consists of a non-magnetic pipe lined with an insulating materials. A pair of magnetic coils are positioned at right angles to the flow and a pair of electrodes penetrate the pipe and its lining. When electrically conductive fluid flows through the pipe beneath the influence of a specific density magnetic area generated by the electromagnetic coil, the quantity of voltage (E) generated across the electrodes is predicted by Faraday’s regulation to be proportional to velocity (V) proportional to the liquid.
E = KV

Where

E = the quantity of voltage generated at the electrode

V = velocity of the fluid flowing through the pipe

K=calibration constant of the meter

Advantages of using electromagnetic flowmeter

High accuracy and stability

Self-checking

Bi-directional measurement

No pressure loss

No transferring components

Possible for hygienic purposes

Available in large sizes

Disadvantages of utilizing electromagnetic flow meters

Cannot be used to measure gases, vapors and liquids containing giant quantities of gasoline

Can not be used to measure liquid media with very low conductivity Electromagnetic flowmeter can not measure media similar to petroleum products or organic solvents

Can not be used to measure excessive temperature media. Currently restricted by the overall industrial electromagnetic flowmeter measuring tube lining supplies and electrical insulation supplies.
Electromagnetic flowmeter is prone to the affect of external electromagnetic interference.
Vortex circulate meter

Vortex flow meters are usually manufactured from 316 chrome steel or Hastelloy and include a blunt physique, a vortex sensor meeting, and transmitter electronics. When a non-streamlined object (also called an obtuse body) is positioned within the path of a excessive Reynolds number flow, the fluid will alternately separate from the item on its downstream sides and, as As the boundary layer separates and coils again on itself, the fluid forms vortices. These vortices result in areas of pressure fluctuations detected by piezoelectric or capacitive sensors. Fluid velocity depends on the frequency of the generated vortices and the Strouhal number and is given by the following equation

V = (fxh)/S

Where

V = average velocity of the fluid circulate

f = frequency of the generated vortex

h = width of the obtuse body

S = variety of Strouhal

S varies with Reynolds number; nonetheless, it’s almost fixed over a variety of flow charges.
In apply, a k-factor representing the number of vortices generated per unit volume is used instead of S. Thus the volumetric move rate is

Q = f/K

Vortex flow meters aren’t usually really helpful for dosing or different intermittent circulate applications. This is as a end result of the drip flow setting of the dosing station may be beneath the minimum Reynolds number restrict of the meter. The smaller the whole batch, the more significant the ensuing error may be.
Low stress (low density) gases will not generate robust sufficient pressure pulses, particularly at low fluid velocities. Therefore, in this kind of service, the gauge is prone to have a poor vary and will not be able to measure low circulate rates. On the other hand, if the lowered vary is suitable and the meter is sized for normal flow, then a vortex flowmeter should be thought-about.
The everlasting pressure loss via the vortex flowmeter is about half that of an orifice flowmeter with about two velocity heads. (Velocity head is outlined as V2/g, the place V is the flow fee and g is the gravitational constant in consistent items.) If the piping and instrumentation are properly sized and identical, the stress drop could additionally be only some pounds per sq. inch. However, downsizing (installing smaller than line dimension gauges) to extend the Reynolds number can increase the head loss to greater than 10 psi. It can also be necessary to make sure that the shrink strain just isn’t decrease than the vapor strain of the method fluid, as this can lead to cavitation. Naturally, if the again strain on the meter is lower than the steam stress, the process fluid will flash and the meter studying shall be meaningless.
The major benefits of vortex move meters are their low sensitivity to adjustments in process circumstances and low put on relative to orifice or turbine flowmeters. In addition, initial and upkeep costs are very low. For these causes, they have gained wider acceptance among customers.
Ultrasonic circulate meter

The velocity of sound propagation in a fluid is dependent upon the density of the fluid. However, if the density is constant, the time of passage (or reflection) of ultrasound can be used to discover out the speed of the flowing fluid.
Ultrasonic move meters measure fluid velocity by transmitting high-frequency sound waves alongside the fluid circulate path. Fluid movement affects the propagation of these sound waves, which might then be Then it may be measured to infer the fluid velocity. There are two main forms of ultrasonic flowmeters: Doppler and transmission time. Both types of ultrasonic flowmeters work by transmitting Both forms of ultrasonic flow meters work by transmitting high-frequency sound waves into the fluid stream (incident pulse) and analyzing the acquired pulses.
Doppler flow meters utilize the Doppler impact, which is a frequency shift brought on by waves emitted or reflected from a transferring object. Doppler move meters mirror sound waves from bubbles or particles within the air stream Particulate materials within the reflection of sound waves, measuring the frequency shift and inferring the fluid velocity and thus the flow rate primarily based on the magnitude of that frequency shift.
In the design of a transit time ultrasonic flowmeter, the time of flight of the ultrasonic signal is measured between two transducers, one upstream and one downstream. With move or The difference in time spent in opposition to the move determines the fluid velocity from which the circulate price is inferred.
Advantages of ultrasonic flowmeters

The electronics in the ultrasonic flowmeter include an ultrasonic flowmeter detector that compensates and adapts to changes in fluid distribution, fluid type and pipe material.
Portable ultrasonic flowmeter converters can be used as a direct technique of successfully figuring out circulate compared to different flow techniques.
Compared to other mechanical flow meters, ultrasonic flow meter converters are inexpensive to make use of and maintain because they haven’t any shifting components in these circulate meters.
They are designed to be very exact and do not impede the circulate of liquids, to enable them to be used for sanitary, corrosive and abrasive liquids.
Disadvantages of ultrasonic move meters

The major drawback of ultrasonic flowmeters is value. Compared to other kinds of mechanical circulate meters, flow meters are very expensive .

Compared to mechanical circulate meters, ultrasonic move meters are extra complex and due to this fact require specialists to restore and keep the circulate meters.
How to choose your digital circulate meter?

The essential elements when selecting a proper circulate meter system are

Media to be measured

Accuracy

Cost

Flow range

Operating necessities

Maintenance

Lifetime

Delivery time

These factors are kind of interrelated. For example – the worth of a circulate meter will increase with accuracy and quality of life. Flowmeter calibration and upkeep are also essential to contemplate.
More articles on flowmeters:
Chilled water flow meter

Ultrasonic move meter working precept

Difference between move meter and circulate transmitter

Working principle of rotameter